- SpO2: Detection scope:0%-100%; Accuracy : ±1% 90%-100%, ±2% 70%-89%
- Resp: Chest impedance method or concentration of carbon dioxide at end of respiration; Scope of chest impedance method,0 time/minute - 100 minutes/minute; Precision of chest impedance method,time/minute; Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg;0.4%vol-9.9%vol; Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby); Detection precision of respiration rate: ±1 time/minute
- Temp: Single/double path; Type: Vascular/surface temperature; Scope: 20℃~50℃; Accuracy: ±0.2℃
- ECG: Full lead: I, II, III, AVL, AVR, AVF and V; Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV; Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s; Band width: 0.05Hz-100Hz(3dB); Heart rate; Scope: 15 times/minute to 300 times/minutes; Accuracy: ±1 time/minute; Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period; Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time; Accuracy: Error rate ; Undetected rate < 20% ; ST section;Scope: ±0.8mV; Precision : < ±0.05mV
- NIBP: Theory Electric oscillator ; Cuff gassing time: less than 15 seconds; First-time gassing pressure: dynamic state 24kPa(180 mmHg); Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg) 18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg); Automatic detection period: 1 minute to 240 minutes; Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 min -90min) and 30min(90 min -240min); Detection scope; Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg); Diastolic pressure:2kPa -29.3kPa(15mmHg -220mmHg); Mean pressure: 2.7kPa~31.3kPa(20mmHg~235mmHg); Detection accuracy ; Static pressure: ±3mmHg; Pulse rate: ±2%
Standard configuration:
ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
Optional:
Dual TEMP
Dual IBP
ETCO2 (side stream)
Thermal recorder
Wall mount
Trolley
Features
12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
Unique digital SPO2 technology can work accurate during motion and low perfusion Anti AC & high-frequency electrosurgical & defibrillator's interference Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events; ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation Audible & visual alarm available, adjustable; Patient information management function
Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room; Optional software upgrading based on USB; Wired/wireless networking with central monitoring system, up to 64 beds in one group
Built-in 3 trace thermal recorder for printing real-time and historical data; Multi-language i.e. English, Spanish, Turkish; Super long life rechargeable Lithium battery up to 4 hours of working time; Suitable for adult, pediatrics and neonate patients