# Microprocessor Control 23L Capacity Auto-Safety Features Sun® Autoclave Sterilizer 23L Vacuum Steam by Moredental

**Brand:** moredental
**Price:** ¥108061
**Availability:** ❌ Out of Stock

## Summary

> 🔧 Elevate Your Sterilization Game!

## Quick Answers

- **What is this?** Sun® Autoclave Sterilizer 23L Vacuum Steam by Moredental by moredental
- **How much does it cost?** ¥108061 with free shipping
- **Is it available?** Currently out of stock
- **Where can I buy it?** [www.desertcart.jp](https://www.desertcart.jp/products/28589507-sun-autoclave-sterilizer-23l-vacuum-steam-by-moredental)

## Best For

- moredental enthusiasts

## Why This Product

- Trusted moredental brand quality
- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Key Features

- • **Real-Time Monitoring:** Displays parameters actively, keeping you informed at all times.
- • **Smart Control System:** Microprocessor technology for precise and intelligent operation.
- • **Versatile Applications:** Perfect for dental, ophthalmic, and laboratory sterilization needs.
- • **Effortless Sterilization:** Designed for frequent use, ensuring your tools are always ready.
- • **Automatic Safety Shutdown:** Protects against excessive temperature and pressure for peace of mind.

## Overview

The Sun® Autoclave Sterilizer 23L by Moredental is a high-capacity, intelligent sterilization solution designed for frequent use in dental, ophthalmic, and laboratory settings. Equipped with advanced microprocessor control and automatic safety features, it ensures reliable and efficient sterilization of heat-resistant instruments.

## Description

Specifications: Rated Voltage: 220V±22V, 50Hz±1Hz, 110V±11V, 60Hz±1Hz Rated Power: 1800VA / 2000VA Sterilizing (Pressure/temp.): 0.9-1.3bar/120ºC, 2.0-2.3bar/120ºC (Both of above are Under Standard Atmospheric pressure) Fuse-Melting pipe: T15A / T30A Capacity of water tank: 2L Water Consumption volume per recycling round: 0.3L Operating Temp: 0-40ºC Inside dimensions: 240*360mm Outside dimensions: 780*520*500 mm Weight: 62kg   Please Note 1. The autoclave must be plced on the horizontal working base. 2. Must use the distilled water for the purpose of lasting the working life. 3. There shall be no clog to the air cooling window on the outer surface. 4. The object apparatus to be sterilized shall be palced on teh device plate with enough clearnace retained in favor of the air circulation inside the sterilizing room. 5. Empty the water inside the cooling water collecting tank frequently. Usually, the cooling water collecting tank shall be emptied once the water storing tank emptied. 6. Must revolve teh door handle to the teminal side while working. 7. Don't open the door of autoclave when seeing the "0" displayed on teh pressure indicator. 8. Not be too closed to the door of the autoclave in case of scald when open the door. 9. Shut off the power before discharging/installing the sealing ring, and the work shall be carried out after further sufficient cooling in case of scald. 10. Don't drag or drop the autoclave during relocation period of the autoclave. 11. The protecting ground shall be reliable. 12. Equipment must be used away from teh magnetic field.

## Features

- 1. The Autoclave is specially designed for the occasions in use of frequent sterilizations. It is equipped with the microprocessor for intelligent control and man-machine interface for convenient operation.
- 2. With the distinctions in displaying parameter and condition actively, evaluating malfunction automatically, shutting off for self-protection automatically in case of excessive temperature and pressure, this type autoclave is reliable product in sterilizing.
- 3. This product can be applied in sterilizing for the tooth device, operation device, Sanitary Material and other heat-resisting articles existing in the Dept. of Stomatology, Ophthalmology and lab.
- 4. Preparation Before Operation I. Before operation, please connect well to the power source. II. Connect the power source hole under the back left side of the autoclave and the power socket by the attached power cable inside the product’s package so as to switch on the autoclave. III. Push down the main power button at the right bottom corner of the front side, when the indicator light is on, it means that the autoclave get through with the shown on the screen. IV. The autoclave is not heated while under such initialization status.

## Images

![Sun® Autoclave Sterilizer 23L Vacuum Steam by Moredental - Image 1](https://m.media-amazon.com/images/I/81TARAqyjZL.jpg)

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.jp/products/28589507-sun-autoclave-sterilizer-23l-vacuum-steam-by-moredental](https://www.desertcart.jp/products/28589507-sun-autoclave-sterilizer-23l-vacuum-steam-by-moredental)

---

*Product available on Desertcart Japan*
*Store origin: JP*
*Last updated: 2026-10-08*