Desertcart purchases this item on your behalf and handles shipping, customs, and support to Japan.
๐ง Stay ahead of the dripโclean, clear, and clog-free every time!
The RectorSeal EZ Trap 83113 is a 3/4" lightweight yet durable condensate trap kit designed for HVAC applications requiring reliable condensate management. Featuring schedule 40 PVC fittings, watertight red caps for easy maintenance, and a transparent body for quick clog inspection, it offers professionals an economical, easy-to-install solution that prevents costly backups and ensures smooth system operation.










| ASIN | B00BMV6QU4 |
| Best Sellers Rank | #56,579 in Tools & Home Improvement ( See Top 100 in Tools & Home Improvement ) #81 in HVAC Ducting |
| Brand | Rectorseal |
| Brand Name | Rectorseal |
| Color | RED AND WHITE |
| Customer Reviews | 4.7 out of 5 stars 813 Reviews |
| Global Trade Identification Number | 00021449831130 |
| Included Components | Rectorseal 83113 EZ 113 Trap, 3/4-Inch |
| Item Dimensions L x W | 2"L x 2"W |
| Item Length | 2 inches |
| Item Type Name | Rectorseal 83113 EZ 113 Trap, 3/4-Inch |
| Item Weight | 6.08 ounces |
| Manufacturer | The Rectorseal Corporation |
| Manufacturer Warranty Description | Limited lifetime warranty |
| Material | Polyvinyl Chloride (PVC) |
| Material Type | Polyvinyl Chloride (PVC) |
| Maximum Pressure | 2 |
| Nominal Wall Thickness | 0.17 inches |
| Outside Diameter | 1.5 inches |
| Product Dimensions | 2"L x 2"W |
| UPC | 021449831130 |
| Unit Count | 1 Count |
K**K
Adjust easily and handy cleanouts
I saw this when I was looking for traps to replace the clogged trap that was installed correctly but had no access for any type of clean out or maintenance. Consequently I'd been using a 5 gallon bucket to catch the condensation until I got everything I needed to replace it. Not something I would recommend but it worked in a pinch and it gave me a new appreciation for how much moisture the air handler or the condenser or whatever takes out of the air every 24 hours. It's been very humid here the last few days and I'd been emptying the bucket once a day with about three or four gallons of water in it. Anyway, this Rectorseal trap was just what I needed as I had to retrofit it in between the two lines. It's adjustable of course until you permanently glue it in place so it was very easy to fit to both sides that were stationary. Of course I have some plumbing experience but even if you don't if you take your time it's easy to fit and the added plus is you have the many different cleanouts. If you look in the photo you can see that I've added two rubbers slip joints that can also be removed so the entire assembly can come out for future cleaning. I've decided that the best bet is to do maintenance on it once a year and make sure the lines are clear so that condensation can flow out. If you forget about it it will build up and eventually start to form clogs which will make the condensation back up and you'll have quite a mess. This seems to be working quite well so far after a day or two with no leaks and a good water flow out of the house. I definitely recommend this particular trap if you want a way to clean out and maintain your condensation line.
Y**N
Simple, Reliable Condensate Trap That Works as Designed
a great productโeasy to install, solid build, and most importantly, no leaks. It fits perfectly on a 3/4-inch condensate line and does exactly what itโs supposed to. The clear design also makes it easy to check for clogs or buildup. Definitely worth the money for a reliable and maintenance-friendly trap.
J**Y
Works well!
No complaints, easy to see when itโs dirty, easy to clean, looks ok.
A**0
Perfect
I've had the AC technicians to my house so many times to figure out why the AC water drain was backing up. They'd tell me the plumbing didn't have enough of a gradient to it and that was they problem. So I had the plumbing redone. It still didn't stop the AC water overflows, which result in the AC shutting off. After opening the pipes myself I realized there was a very strong suction back towards the AC unit. This was strong enough to suck the water back into the unit that should have been draining. (To be fair, that might have not happened with a steeper slope on the drain pipes.) They might have been partial right, but after some research I found out about this device. The U shape filled with water is enough to stop the suction from pulling water back into the AC unit. The full water in the U curve stops the air inflow. Then as water trickles in gravity takes over and it drips out the drain pipe. Ingenious device. Easy to install. I can't believe professional AC technicians from 2 different companies didn't know to put one of these in. They sell a version of these at hardware stores, but this one is much better. Easier to work with. The fact that it is clear and has valves you can open means you can see if it is clogging up and easily open it for cleaning. Get this one. I don't think I'll have to touch the AC unit again.
T**Y
Worked really good on my York 90% furnace drain
Worked really well, I did have to put it on an angle to work.
S**R
Love this product.
This product is outstanding. I fully recommend the product. I do want to point out that you need to glue each piece together before running water through the pipes.
C**Y
Easy clean out plus easy install buy this and the glue and a PVC fitting! In my install!
Furnace man did a tune up and said I needed one of these. He would do it for 550.00 dollars! I said I would wait! He left I bought this EXACT same item he had for 15.00 dollars installed myself in 5 minutes I'll never call them back!
A**.
Fixed my issue immediately
This one purchase fixed my issue immediately. I kept on trying to cheap out on buying this because I thought I could do it cheaper with my own design, but this literally would have saved me ten to fifteen hours of scratching my head of why my fixes werenโt working. Just spend the money and buy this is you are having overflowing issues with your HVAC system. Chances are that you need this. Wish I bought it sooner.
P**S
Great design, easy to install
This is a great design. The installers for my furnace used a solid PVC trap that was all glued together and was impossible to clean. It clogged up with dust and gunk and I had to cut it off and replace it after my condensate pan overflowed. This is a very good solution to replace that, as it allow you to easily inspect the drain and clean it out with a brush (not included). I've included a photo of my install. It glues together easily with PVC cement and standard 3/4" PVC fittings. I used purple PVC primer as well, but it was not really necessary since this isn't a pressurized application. Overall I'm very satisfied with the product.
S**E
Make sure you have enough depth between the bottom of the inlet and the bottom of the outlet pipe.
I like this P-trap as you can see any dirt that is in the bottom as it is clear tubing. Then remove the caps and clean it out. For my heat pump air handler I had to add a short piece of pipe to the taller section as it needed a 3" drop between the inlet and outlet pipes because of the negative pressure developed in the air handler during operation, otherwise that negative pressure would suck air back it to and not drain properly. I also bought a second one for my Vanee HRV. It worked as it came.
F**B
Just what i needed
I realized recently, that my hvac drain tube had no p-trap inline, and so i got this kit. Went on well, I glued the ends of the "U" pipe. Works well and makes it easy to clean line.
R**W
as advertised
quick delivery and easy installation. clear tubing lets you check that there is water in the trap.
E**N
Useful product, with adjustment
Needs some adjustment if AC system is negative pressure: additional pipe added to the left side to create a deeper trap . Otherwise, like the clear bottom and the caps... works fine, easy to clean. Glad I bought it as my plumber did not have one and I was able to provide this one to get the result I wanted.
Trustpilot
1 week ago
1 month ago